Đang truy cập: 1 Trong ngày: 45 Trong tuần: 193 Lượt truy cập: 420627 |
CoriolisMaster Series of Coriolis Mass Flowmeters
ABB’s CoriolisMaster series delivers world-class coriolis mass flowmeters for a wide variety of applications.
Wide range of meter sizes provide precise measurement of massflow, volume flow, density, temperature and concentration. ABB's CoriolisMaster series has a history of success in a wide variety of industries and applications. With innovations like sensor memory, easy set-up and no up or downstream piping requirements - they save time and money during installation, commissioning and maintenance.
Benefits of using ABB’s CoriolisMaster flowmeters:
− Save cost by making several measurements with one device
− Reduce flowmeter maintenance by up to 90 %
− No mechanical wear and minimize installation issues
− Save up to 25 % on pump power
− Save critical installation space
Our Offering
1. One of the most cost saving meters on the market today with the most innovative new transmitter system - save on installation and handling, pump power and spares cost with this new class-leading Coriolis mass flowmeter.
FCB400 series
CoriolisMaster FCB430 and FCB450
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB430
– Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
– Density: 10 g/l
FCB450
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB430
– -50 to 160 °C (-58 to 320 °F)
FCB450
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 5 modular I/Os
– HART 7.1 - Power supply
– 11 to 30 V DC, 110/230 V AC
2. All the outstanding benefits of the FCB400 series is available as a hygienic version for superb and certified cleanability.
FCH400 series
CoriolisMaster FCH430 and FCH450
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Hygienic approvals
– EHEDG and FDA material compliant - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH430
– Mass and volume: 0.4 % o. r. / 0.25 % o. r. / 0.2 % o. r.
– Density: 10 g/l
FCH450
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH430
– -50 to 160 °C (-58 to 320 °F)
FCH450
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 5 modular I/Os
– HART 7.1 - Power supply
– 11 to 30 V DC, 110/230 V AC
3. Offering high speed RS485 Modbus communication and 2 digital outputs, ideal for integration into systems and providing accurate high speed and density measurement.
FCB100 series
CoriolisMaster FCB130 and FCB150
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCB150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB130
– -50 to 160 °C (-58 to 320 °F)
FCB150
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 digital out (pulse, frequency, contact)
– Modbus - Power supply
– 11 to 30 V DC
4. Offering the hygienic sensor with EHEDG approval with high speed RS485 Modbus communication and 2 digital outputs, ideal for integration into systems and providing accurate high speed and density measurement.
FCH100 series
CoriolisMaster FCH130 and FCH150
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH130
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCH150
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH130
– -50 to 160 °C (-58 to 320 °F)
FCH150
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 digital out (pulse, frequency, contact)
– Modbus - Power supply
– 11 to 30 V DC
5. Precision measurement for extremly low flow rates and line sizes.
FCM2000-MS2
CoriolisMaster FCM2000-MS2
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 1.5 (1/16 in.) / 0 to 65 kg/h (143 lb/h)
– DN 3 (1/10 in.) / 0 to 250 kg/h (551 lb/h)
– DN 6 (1/4 in.) / 0 to 1,000 kg/h (2,205 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Maximum process pressure
– up to 500 bar (7250 psi) for details and restrictions see data sheet - Accuracy for liquids
– Massflow: 0.4 % o. r. / 0.25 % o. r. / 0.15 % o. r. / 0.1 % o. r.
– Density: 4 g/l or 1 g/l - Measuring medium temperature
– -50 to 180 °C (-58 to 356 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in - Power supply
– 24 V AC/DC, 110/230 V AC
6. One of the most cost saving meters on the market today - save on installation, pump power with this Coriolis mass flowmeter.
FCB300 series
CoriolisMaster FCB330 and FCB350
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 15 (1/2 in.) / 0 to 8,000 kg/h (17,637 lb/h)
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h)
– DN 100 (4 in.) / 0 to 520,000 kg/h (1,146,404 lb/h)
– DN 150 (6 in.) / 0 to 860,000 kg/h (1,895,975 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Marine approval
– DNV - GL - Wetted materials
– 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
FCB330
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCB350
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCB330
– -50 to 160 °C (-58 to 320 °F)
FCB350
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in
– HART - Power supply
– 24 V AC/DC, 110/230 V AC
7. All the outstanding benefits of the FCB300 series ia available as a hygienic version for superb and certified cleanability.
FCH300 series
CoriolisMaster FCH330 and FCH350
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 25 (1 in.) / 0 to 35,000 kg/h (77,162 lb/h)
– DN 50 (2 in.) / 0 to 90,000 kg/h (198,416 lb/h)
– DN 80 (3 in.) / 0 to 250,000 kg/h (551,156 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Hygienic approvals
– EHEDG and FDA material compliant - Wetted materials
– 1.4404 / 1.4435 (316L) - Accuracy for liquids
FCH330
– Mass and volume: 0.4 % o. r. / 0.25 % o. r.
– Density: 10 g/l
FCH350
– Mass: 0.15 % o. r. / 0.1 % o. r., volume: 0.15 % o. r.
– Density: 2 g/l or 1 g/l - Measuring medium temperature
FCH330
– -50 to 160 °C (-58 to 320 °F)
FCH350
– -50 to 205 °C (-58 to 400 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in
– HART - Power supply
– 24 V AC/DC, 110/230 V AC
8. Unique S-shape tube and modular design for tough measurement requirements.
FCM2000-MC2
Data
General specifications:
- Nominal sizes / measuring ranges
– DN 20 (3/4 in.) / 0 to 6,000 kg/h (13,227 lb/h)
– DN 25 (1 in.) / 0 to 9,600 kg/h (21,146 lb/h)
– DN 40 (1.5 in.) / 0 to 28,500 kg/h (62,832 lb/h)
– DN 50 (2 in.) / 0 to 55,200 kg/h (121,695 lb/h)
– DN 80 (3 in.) / 0 to 147,600 kg/h (325,402 lb/h)
– DN 100 (4 in.) / 0 to 249,600 kg/h (550,274 lb/h)
– DN 150 (6 in.) / 0 to 660,000 kg/h (1,455,051 lb/h) - Ex approvals
– ATEX zone 0/1/2, cFMus Div 1/2 and zone 0/1/2, NEPSI 0/1/2 - Wetted materials
– 1.4571 (316Ti) or 1.4404 / 1.4435 (316L) or Hasteloy C - Accuracy for liquids
– Massflow: 0.4 % o. r. / 0.25 % o. r. / 0.15 % o. r. / 0.1 % o. r.
– Density: 4 g/l or 1 g/l - Measuring medium temperature
– -50 to 200 °C (-58 to 396 °F) - Outputs
– 2 current outputs, 1 pulse, 1 contact out/in - Power supply
– 24 V AC/DC, 110/230 V AC
1. Data sheet - CoriolisMaster FCB430, FCB450, FCH430, FCH450 - Coriolis mass flowmeter
7. Data sheet - CoriolisMaster FCB330, FCB350, FCH330, FCH350 - Coriolis mass flowmeter
Người gửi / điện thoại
CONTACT
HOP VIET ENG CO., LTD
Office: 217A Quach Dinh Bao Str, Phu Thanh Wad, Tan Phu Dist, HCMC, VietNam
Add: 15 Le Thiet Str, Phu Tho Hoa Ward, Tan Phu Dist, HCMC, Vietnam
Tel: (+84 28) 6267 5677 - Fax: (+84 28) 6265 5066
Email: info@hopviet.vn - Website: www.hopviet.vn