TU DIEN10 TU DIEN09 TU DIEN07 TU DIEN01 CENTORK07 CENTORK06 CENTORK04 CENTORK03 ABB15 ABB13 ABB12 ABB05 Van bướm Van tay quay Unik DN500 Van bướm tay quay Unik DN450 UKV - 2012R Van bướm tay quay Unik DN400 Van bướm tay quay Unik DN350 UKV - 2012R Van bướm tay quay Unik DN300 Van bướm tay quay Unik DN250 Van bướm tay quay Unik DN200 Van bướm tay quay Unik DN150

Đang truy cập: 57
Trong ngày: 248
Trong tuần: 1010
Lượt truy cập: 321010

Email
Mật khẩu
Nhớ mật khẩu

Quên mật khẩu | Đăng ký

Conductivity Measurement

Our broad range of conductivity cells encompasses three measuring techniques: 2-electrode cells for µS/cm ranges, 4 and 6 electrode sensors for mS/cm levels and non-contact, electrode-less sensors.
Multi-electrode and electrode-less (toroidal) sensors tend to be used for applications with aggressive chemicals or where there can be sensor coating or fouling.
Comprehensive mounting methods are available to suit the majority of process applications: insertion, flow-through, immersion and retractable.

 


2-Electrode Contacting Cells - Range 0 ... 10,000 µS/cm

High accuracy technique for trace conductivities from ultrapure water to industrial rinse waters. An alternating current is passed between two electrodes in contact with a solution. The transmitter converts the resultant potential difference into conductivity, concentration or specific resistance.

Table 1 of 3
AC211AC212AC213AC221
>>read more

>>read more>>read more>>read more
Electrode MaterialCarbonCarbonCarbonStainless steel
Cell Constant0.1 or 1.00.1 or 1.00.1 or 1.00.01 or 0.1
Temperature100 °C (212 °F)100 °C (212 °F)90 °C (194 °F)*200 °C (392 °F)**
Pressure6.6 bar (100 psi)6.6 bar (100 psi)--20 bar (290 psi)
Submersion----10 m
(AC213/0)
--
Immersion----1 or 2 m
(AC213/1 & AC213/2)
--
Flow-through--1/2 in. BSP or NPT--3/8 in. BSP or NPT
Screw-in Insertion1 in. BSP or NPT----3/4 in. BSP or NPT
Retractable--------
Tri-Clamp Insertion--------
* AC213/1 & /2 only** When used with high temperature cable


Table 2 of 3
22782085TB25TB254
>>read more>>read more>>read more>>read more
Analytical Conductivity Sensor
Electrode MaterialStainless steelStainless steelStainless steelStainless steel
Cell Constant0.050.05 or 0.10.01, 0.1 or 1.00.01, 0.1 or 1.0
Temperature130 °C (266 °F)110 °C (230 °F)175 °C (347 °F)100 °C (212 °F)
Pressure10.5 bar (150 psi)10.5 bar (150 psi)8.6 bar (125 psi)6.9 bar (100 psi)
Immersion---3/4 in. NPT
Flow-through----
Screw-in Insertion---1 in. NPT
Retractable-1-1/2 in. BSP or NPT--
Tri-Clamp Insertion2 in.-1-1/2 in., 2 in., 2-1/2 in., 3 in.-


Table 3 of 3
TB26TB264TB27
>>read more>>read more>>read more
Analytical Conductivity Sensor
Electrode MaterialStainless steelStainless steelStainless steel
Cell Constant0.01, 0.1 or 1.00.01, 0.1 or 1.00.01, 0.1 or 1.0
Temperature200 °C (392 °F)200 °C (392 °F)200 °C (392 °F)
Pressure6.9 bar (100 psi)13.8 bar (200 psi)20.7 bar (300 psi)
Immersion1/2 in. NPT--
Flow-through-1/2 in. NPT-
Screw-in Insertion3/4 in. NPT--
Retractable1-1/2 in. NPT-1-1/2 in. NPT
Tri-Clamp Insertion---


4-Electrode Contacting Cells - Range 0 ... 2,000 mS/cm
Auto-compensating technology for high level conductivity and concentration measurements in high-coating processes. Provides an alarm when cleaning is required.

Table 1 of 2
TB451TB454TB457TB461
>>read more>>read more>>read more>>read more
Electrode MaterialStainless steelStainless steelStainless steelStainless steel
Temperature140 °C (284 °F)100 °C (212 °F)175 °C (347 °F)200 °C (392 °F)
Pressure6.9 bar (100 psi)6.9 bar (100 psi)8.6 bar (125 psi)15.5 bar (225 psi)
Immersion-3/4 in. NPT-1/2 in. NPT
Flow-through----
Screw-in Insertion-1 in. NPT-3/4 in. NPT
Retractable--1-1/4 in. NPT
Tri-Clamp Insertion1 in. and 1-1/2 in.-1-1/2 in., 2 in., 2-1/2 in., 3 in.-


Table 2 of 2
TB464TB468TB47
>>read more>>read more>>read more
Analytical Conductivity SensorAnalytical Conductivity Sensor
Electrode MaterialStainless steelHastelloy CStainless steel
Temperature200 °C (392 °F)Up to 140 °C (284 °F)200 °C (392 °F)
Pressure13.8 bar (200 psi)Up to 6.9 bar (100 psi)20.7 bar (300 psi)
Immersion---
Flow-through1/2 in. NPT--
Screw-in Insertion-3/4 in. NPT-
Retractable-1 in. NPT1-1/4 in. NPT
Tri-Clamp Insertion---

Electrodeless Sensors - Range 0 ... 2,000 mS/cm

Non-contact technique providing immunity to polarisation, oily fouling and non-conducting coatings until gross fouling occurs. Measurement of the magnitude of induced AC into a closed loop of solution using two embedded toroids.
TB4042TB4043
>>read more>>read more
Analytical Conductivity Sensor
Body MaterialPEEKPEEK
Temperature200 °C (392 °F)121°C (250 °F)
Pressure6.6 bar (100 psi)6.6 bar (100 psi)
Immersion3/4 in. NPT-
Flow-through--
Screw-in Insertion1-1/2 in. NPT-
Rectractable1-1/2 in. NPT-
Tri-Clamp Insertion-2 in.

Phản hồi

Người gửi / điện thoại

Nội dung

 



Cấu hình chữ chạy để sử dụng chức năng này

CONTACT

HOP VIET ENG CO., LTD  

Office: 217A Quach Dinh Bao Str, Phu Thanh Wad, Tan Phu Dist, HCMC, VietNam

Add: 15 Le Thiet Str, Phu Tho Hoa Ward, Tan Phu Dist, HCMC, Vietnam

Tel: (+84 28) 6267 5677  -  Fax: (+84 28) 6265 5066

Email: info@hopviet.vn  -  Website: www.hopviet.vn

Hotline: +84 903056455